MODEL
3000
USER MANUAL
Premier Series
Non-Programmable
Single Stage Heat/Cool
Digital Thermostat
Compatible with low voltage single stage gas,
oil or electric heating or cooling systems,
including single stage heat pumps. This
thermostat can also be used on 250mv to
750mv millivolt heating only systems. Do not
use this thermostat on applications with
voltages above 30 Volts AC.
READ ALL INSTRUCTIONS BEFORE PROCEEDING
© 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 3000-100-006
CONTENTS
WARNING!
Important Safety Information
SPECIFICATIONS
INSTALLATION
TESTING YOUR NEW THERMOSTAT
PROGRAMMING USER SETTINGS
ADDITIONAL OPERATION FEATURES
TROUBLESHOOTING
WIRING DIAGRAMS
SPECIFICATIONS
1
1
Electrical Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal
2 amp total maximum load (all terminals)
Control Range: 45˚ - 90˚ F (7˚ - 32˚ C)
Accuracy: +/- 1˚ F (+/- .5˚ C)
• DC Power: 3.0 Volt DC (2 AA Alkaline batteries included)
Compatibility with low voltage single stage gas, oil or electric heating or cooling
systems, including single stage heat pumps. This thermostat can also be used on
250mv to 750mv millivolt heating only systems.
Terminations: Rc, Rh, G, W, Y, B, O
INSTALLATION
2
2.1
Replacing Existing Thermostat
1.
Always turn off power to the air conditioning or heating system prior to removing
existing thermostat.
2.
Remove the cover of your old thermostat and locate the wire terminals. Do not remove
wires from terminals yet.
3.
Using small pieces of masking tape, label wires prior to removal from terminals. Use
the chart below to determine the new terminal designations for your new thermostat.
Old Terminal from New Terminal for
Existing Thermostat New Thermostat Terminal Description
V or Rc Rc Cooling Transformer
M, 4, Rh, or R Rh Heating Transformer
G or F G Fan Control
H, W or 4 W Heating Control
Y Y Cooling Control
B B Reversing Valve (Heating)
O O Reversing Valve (Cooling)
C None-Cap the wire 24 Volt AC, Transformer Common
1
2
3
4
5
6
7
Always turn off power to the air conditioning or heating system prior to installing,
removing, cleaning or servicing thermostat.
• Read manual thoroughly prior to installing, programming or operating thermostat.
This thermostat is designed for use with a 24 Volt-AC low voltage single stage gas,
oil or electric heating or cooling systems, including single stage heat pumps. This
thermostat can also be used on 250mv to 750mv millivolt heating only systems.
• Do not use this thermostat on applications with voltages above 30 Volts AC.
This thermostat requires two (2) properly installed "AA" alkaline batteries to
provide power for the thermostat to properly control the system operation.
The system must have 24 Volt AC power present for proper system operation and control.
Wiring must conform to all building codes and ordinances as required by local and
national code authorities having jurisdiction.
• Do not short (or jumper) across terminals on the gas valve or at the heating or
cooling system control board to test the thermostat installation. This could
damage the thermostat and void the warranty.
• Do not select COOL mode of operation if the outside temperature is below 50˚ F
(10˚ C). This could damage the controlled cooling system and cause personal injury.
This thermostat should only be used as described in this manual. Any other use is
not recommended and will void the warranty.
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - USER MANUAL

MODEL3000USER MANUALPremier SeriesNon-ProgrammableSingle Stage Heat/CoolDigital ThermostatCompatible with low voltage single stage gas, oil or electri

Page 2 - NEW THERMOSTAT

2 3INSTALLATION22.2Installing Your New Thermostat cont.9. Fasten the sub-base to wall using supplied screws.10. Connect wires to quick wiring ter

Page 3 - OPERATION FEATURES

4PROGRAMMINGUSER SETTINGS44.1Default Thermostat SettingsFunction Status After ResetOperation Mode Normal Operating ModeRoom Temperature 70˚ F (21.0

Page 4

76NOTE: The installer can reset the thermostat and bypass the compressor protection feature by pressing the RESET button. This will erase all user pr

Page 5 - TROUBLESHOOTING

89TROUBLESHOOTING6SYMPTOM POTENTIAL SOLUTIONSYMPTOM POTENTIAL SOLUTIONThermostat turns heating or cooling system on too often or not often enough.Inc

Page 6 - Store this

10WIRING DIAGRAMS7Rc Rh GFactory InstalledJumperTypical 4-Wire Single Transformer Heating and Cooling SystemW Y B OHeatControlFanControlCoolControl24